Residential fire sprinkler & water mist pumping solutions — BS 9251:2021 Call 0800 040 7738 sales@aquaguardpumps.co.uk

Home / Technical

Technical data

Downloads, full model-by-model performance data with pump curves, and the standards the AquaGuard range is built to.

Downloads

Brochures, datasheets & manuals

Product documentation for the AquaGuard range — click any item to download the PDF.

AG Series · horizontal

AG model data

BS 9251:2021 Cat 1–4 · 25–500 L/min · 1–10 Bar.

AG75 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Suction / dischargeWeight (kg)
AG75-060.33230/1/502.516.25DN32 / DN2530
AG75-100.45230/1/503.016.3DN32 / DN2530
AG75-140.55230/1/503.717.1DN32 / DN2531
AG75-170.75230/1/504.317.4DN32 / DN2532
AG75-240.9230/1/505.426.2DN32 / DN2533
AG75-281.1230/1/506.026.5DN32 / DN2534
AG75-341.3230/1/506.929.0DN32 / DN2537
AG75 series pump curves: total head and NPSH in metres plotted against flow in litres per minute
AG75 series — total head & NPSH vs flow (L/min)
AG100 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Suction / dischargeWeight (kg)
AG100-100.45230/1/503.016.2DN32 / DN2530
AG100-160.55230/1/503.918.0DN32 / DN2530
AG100-240.9230/1/505.325.5DN32 / DN2532
AG100-301.1230/1/506.226.0DN32 / DN2533
AG100-381.3230/1/507.330.7DN32 / DN2536
AG100-441.5230/1/508.231.0DN32 / DN2537
AG100-491.85230/1/5010.533.0DN32 / DN2543
AG100-59-T2.2400/3/504.341.28DN32 / DN2544
AG100 series pump curves: total head and NPSH in metres plotted against flow in litres per minute
AG100 series — total head & NPSH vs flow (L/min)
AG150 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Suction / dischargeWeight (kg)
AG150-120.75230/1/504.316.2DN40 / DN3231
AG150-211.1230/1/506.318.0DN40 / DN3232
AG150-311.5230/1/508.225.5DN40 / DN3236
AG150-39-E2.2230/1/5012.373.0DN40 / DN3242
AG150-39-T2.2400/3/504.126.0DN40 / DN3242
AG150-46-E2.2230/1/5012.373.0DN40 / DN3243
AG150-46-T2.2400/3/504.730.7DN40 / DN3243
AG150-59-T3.0400/3/505.552.8DN40 / DN3245
AG150-67-T3.0400/3/506.057.6DN40 / DN3246
AG150 series pump curves: total head and NPSH in metres plotted against flow in litres per minute
AG150 series — total head & NPSH vs flow (L/min)
AG250 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Suction / dischargeWeight (kg)
AG250-171.5230/1/507.727.8DN50 / DN4040.2
AG250-29-T2.2400/3/504.543.2DN50 / DN4044.2
AG250-40-T3.0400/3/505.754.8DN50 / DN4048.2
AG250-51-T4.0400/3/507.056.7DN50 / DN4062
AG250-64-T5.5400/3/509.378.2DN50 / DN4071
AG250-75-T5.5400/3/5010.386.6DN50 / DN4072.6
AG250 series pump curves: total head and NPSH in metres plotted against flow in litres per minute
AG250 series — total head & NPSH vs flow (L/min)
AG300 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Suction / dischargeWeight (kg)
AG300-20-T2.2400/3/504.341.3DN50 / DN4044.2
AG300-31-T3.0400/3/505.956.6DN50 / DN4048.2
AG300-44-T4.0400/3/507.762.4DN50 / DN4062
AG300-57-T5.5400/3/5010.386.5DN50 / DN4071

Pump curves for the AG300 range will be added with the AG300 data sheet. Flow / pressure performance is available now in the pump selection tool.

AGV Series · vertical

AGV model data

BS 9251:2021 Cat 2–4 · 130–700 L/min · 1–16 Bar. Selected models shown — full configurations available on request.

AGV150 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Suction / dischargeWeight (kg)
AGV150-44-M2.2230/1/508.073.6DN40 / DN4065
AGV150-44-T2.2400/3/504.642.3DN40 / DN4065
AGV150-61-T3.0400/3/505.649.3DN40 / DN4069
AGV150-79-T4.0400/3/508.085.6DN40 / DN4079
AGV150-95-T4.0400/3/508.085.6DN40 / DN4081
AGV150 series pump curves: total head and NPSH in metres plotted against flow in litres per minute
AGV150 series — total head & NPSH vs flow (L/min)
AGV250 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Suction / dischargeWeight (kg)
AGV250-29-T3.0400/3/505.649.3DN50 / DN5076
AGV250-51-T4.0400/3/508.085.6DN50 / DN5083
AGV250-73-T5.5400/3/5010.2114.2DN50 / DN50117
AGV250-96-T7.5400/3/5014.4149.8DN50 / DN50122
AGV250-131-T11400/3/5019.9193.1DN50 / DN50151
AGV250 series pump curves: total head and NPSH in metres plotted against flow in litres per minute
AGV250 series — total head & NPSH vs flow (L/min)
AGV350 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Suction / dischargeWeight (kg)
AGV350-35-T5.5400/3/5010.2114.2DN50 / DN50113
AGV350-62-T7.5400/3/5014.4149.8DN50 / DN50118
AGV350-87-T11400/3/5019.9193.1DN50 / DN50146
AGV350-108-T11400/3/5019.9193.1DN50 / DN50149
AGV350 series pump curves: total head and NPSH in metres plotted against flow in litres per minute
AGV350 series — total head & NPSH vs flow (L/min)
AGV500 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Suction / dischargeWeight (kg)
AGV500-27-T5.5400/3/5010.2114.2DN65 / DN50143
AGV500-34-T5.5400/3/5010.2114.2DN65 / DN50147
AGV500-40-T7.5400/3/5014.4149.8DN65 / DN50149
AGV500-45-T7.5400/3/5014.4149.8DN65 / DN50149
AGV500-52-T7.5400/3/5014.4149.8DN65 / DN50156
AGV500-60-T11400/3/5019.9193.1DN65 / DN50178
AGV500-65-T11400/3/5019.9193.1DN65 / DN50178
AGV500-73-T11400/3/5019.9193.1DN65 / DN50182
AGV500-78-T11400/3/5019.9193.1DN65 / DN50182
AGV500-84-T15400/3/5026.8257.3DN65 / DN50188
AGV500-92-T15400/3/5026.8257.3DN65 / DN50192
AGV500-97-T15400/3/5026.8257.3DN65 / DN50192
AGV500-102-T15400/3/5026.8257.3DN65 / DN50192
AGV500 series pump curves: total head and NPSH in metres plotted against flow in litres per minute
AGV500 series — total head & NPSH vs flow (L/min)

AP Series · AquaPOD

AquaPOD model data

BS 9251:2021 Cat 1 · 25–110 L/min · 1–5 Bar · enclosure 500 × 480 × 240 mm.

AquaPOD AP75 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Dimensions (mm)Weight (kg)
AP75-060.33230/1/502.516.25500×480×24027
AP75-140.55230/1/503.717.1500×480×24028
AP75-240.9230/1/505.426.2500×480×24030
AquaPOD AP75 series pump curves: total head and NPSH in metres plotted against flow in litres per minute
AquaPOD AP75 series — total head & NPSH vs flow (L/min)
AquaPOD AP100 series
ModelMotor (kW)Supply (V/ph/Hz)FLC* (A)Start (A)Dimensions (mm)Weight (kg)
AP100-100.45230/1/503.016.2500×480×24027
AP100-240.9230/1/505.325.5500×480×24029
AP100-381.3230/1/507.330.7500×480×24033
AquaPOD AP100 series pump curves: total head and NPSH in metres plotted against flow in litres per minute
AquaPOD AP100 series — total head & NPSH vs flow (L/min)

*FLC = full load current, indicated per line phase — multiply by the number of phases when sizing UPS supplies. Soft starters are an optional extra on motors over 3 kW.

Compliance

Standards & approvals

BS 9251:2021

Sprinkler systems

Design, installation, components, water supplies, commissioning, maintenance and testing for life-safety sprinkler systems in residential and domestic premises.

BS 8458:2015

Water mist systems

For residential and domestic water mist fire suppression installations.

LPCB

Approved switches

LPCB-approved twin pressure switch with independent internal switches.

BS EN 12259-2

Flow switch

Approved flow switch fitted as standard across the range.

WRAS

Stainless steel pump

WRAS-listed pump with 316 stainless steel manifold.

IP55

Controller enclosure

Rated to prevent water and dust ingress, pre-wired with fire-rated cable.

Specifying a fire sprinkler pump set? Let's get the sizing right.

Talk to the team — pre-built, tested and ready to install.

Request a quote